info@almontazar.com       +91-22-25126500 :: Pressure,Differential Pressure,Temperature,Level,Flow,Process Control,valves,Test Equipments

Series CDTR Carbon Dioxide/RH/Temperature Transmitter

Series CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, and temperature in one device, system integrators are able to lower installation time of mounting multiple housings, while lowering material cost at the same time. Even with the three sensors combined into a single unit, replacement cost is not increased due to the pluggable nature of the humidity sensor, which allows it or the temperature to be replaced at a fraction of the cost of a new CO2 transmitter.

Like our popular Series CDT Carbon Dioxide Transmitter, a single-beam dualwavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. The single-beam dual-wavelength sensor technology provides a higher level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. In order to achieve the best possible accuracy, the Series CDTR also includes digital barometric pressure adjustment and the ability to field-calibrate the sensor.

Universal outputs for both carbon dioxide and relative humidity allow users to select the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually any building management controller. Additionally, passive thermistor or RTD sensor can be ordered for a temperature output. An optional relay for the carbon dioxide measurement can be used to control exhaust fans, open actuated windows or dampers, or signal a light or horn. For applications that require visual indication, the wall mount configurations of the Series CDTR can be ordered with an integral LCD display. When ordering a duct mount configuration or a wall mount configuration without the display, the Model A- 449 or A-449A remote LCD display can plug into the miniature connector port on the transmitter. The display can be configured to display temperature only, relative humidity only, CO2 only, CO2 and humidity, or CO2 and temperature. Push buttons are standard on all configurations of the transmitters for access to the menu structure, but wall mount configurations can be ordered without the buttons. To prevent tampering, the action of the buttons can be locked out using an internal jumper selection. Menu items that can be accessed via the push buttons include: engineering units, relay output set points, display configuration, transmitter output scaling, ambient barometric pressure, and field calibration of the transmitter.

*For buildings occupied 24 hours per day, it is recommended that calibration be verified every 6 to 12 months depending on application.

Product Applications

  • On Demand Ventilation

Testimonial

” I would like to put on record my appreciation of the service you provide. Your prompt delivery/collection service is very useful as it minimizes equipment downtime. I have always found the work carried out to be of the highest quality. The calibration paperwork received is always clear and concise. In short it has made our compliance with quality standards easier. I would recommend your calibration service to anyone.”
“ PERFECT is the most suitable word to describe their service “

“I did the Right Choice ,cost effective,Great Service”

Slide background
Slide background
Slide background
Slide background
Dwyer Differential Pressure, Dwyer Air/Inert Gases, Dwyer Differential Pressure Gages, Dwyer Dial Gauges For Air/Inert Gases, Dwyer Controllers For Air/Inert Gases, Dwyer Data Loggers, Dwyer Switches For Air/Inert Gases, Dwyer Manometers, Dwyer Transmitters For Air/Inert Gases, Dwyer Wet/Wet Differential Pressure, Dwyer Wet/Wet Transmitters, Dwyer Wet/Wet Controllers, Dwyer Wet/Wet Dial Gauges, Dwyer Wet/Wet Switches, Dwyer Gauge/Absolute/Vacuum, Dwyer Pressure Gauges, Dwyer Digital Pressure Gauges, Dwyer Pressure Transmitters, Dwyer Pressure Switches, Dwyer Pressure Controllers, Dwyer Pressure Data Loggers, Dwyer Air QualityDwyer Air Velocity & Flow, Dwyer Air Velocity & Flow Switches, Dwyer Air Velocity & Flow Transmitters, Dwyer Air Velocity & Flow Sensors, Dwyer CO & CO2 Transmitters, Dwyer Temperature & Humidity, Dwyer Temperature & Humidity Switches, Dwyer Temperature & Humidity Transmitters, Dwyer Flow, Dwyer Flow Gauges, Dwyer Flowmeters, Dwyer Flow Sensors Dwyer Sight Flow Indicators, Dwyer Flow Switches, Dwyer Flow Transmitters, Dwyer Rotameters, Dwyer Temperature, Dwyer Temperature Controllers, Dwyer Temperature Data Loggers, Dwyer Temperature Dial Gauges, Dwyer Temperature Digital Thermometer or Indicator, Dwyer Temperature Sensors, Dwyer Temperature Switches, Dwyer Temperature Thermometers, Dwyer Temperature Thermowell, Dwyer Temperature Transmitters, Dwyer Level, Dwyer Level Controller, Dwyer Level Data Loggers, Dwyer Level Indicator, Dwyer Level Switches, Dwyer Level Transmitters, Dwyer Adjustable Differential Pressure SwitchesDwyer Vacuum Switches, Dwyer Vibration Switches, Dwyer Differential Pressure Controllers, Dwyer CO & CO2 Transmitters, Dwyer Instruments in MumbaiAerosense in Mumbai